Note on the use of mold incubator

Dongpu Instrument Mold Incubator is suitable for scientific research, colleges and production departments such as environmental protection, sanitation and epidemic prevention, drug testing, agriculture, livestock and aquatic products. It is a special constant temperature equipment for water body analysis and BOD measurement, cultivation, preservation, plant cultivation and breeding experiments of bacteria, molds and microorganisms.
1. Adjust the height with the bottom adjustment screw of the mold incubator to make the box stable.
2. Plug in the power socket (the power supply should be well grounded), press the power switch, the display is bright, and the display shows the actual temperature and humidity in the incubator room.
3. Installation of the humidifier: Plug the power plug of the humidifier into the power socket on the back of the instrument, and then connect the humidification tube of the instrument to the humidifier. The connection must be tightly connected. The water in the humidifier tank must be properly operated according to the instructions.
4. Temperature adjustment: press the temperature setting button, the digital display is the set value, rotate the temperature to adjust the potentiometer to the desired temperature value, release the button, the digital display is the actual temperature in the culture chamber. At this time, if the actual temperature in the incubator is smaller than the set temperature, the heating indicator light is on, and the heater starts to heat; if the actual temperature in the incubator is larger than the set temperature, the cooling indicator light is on, and the refrigeration system starts to cool; If the cooling indicator is dark, the incubator is at a constant temperature.
5. Humidity adjustment: press the humidity setting button, the digital display is the set value, rotate the humidity to adjust the potentiometer to the desired humidity value, release the button, the digital display is the actual humidity in the mold incubator. When the actual humidity in the culture chamber is less than the set humidity, the humidification humidifies the culture chamber at this time, and the humidification indicator light is on; when the actual humidity in the culture chamber is greater than the set humidity value, the humidifier stops working at this time, and the humidification indicator light Off.
6. If there is no need to sterilize in the box, the sterilization switch on the panel should be placed in the “off” position.
7. When the temperature is set, the temperature control knob cannot be rotated back and forth many times, so as to avoid frequent compressor start-up, causing overload phenomenon of the compressor and affecting the service life of the compressor.
8. Care must be taken when handling. The angle between the water and the plane should not be less than 45°.
9. When the temperature is low, the water in the water tray at the bottom of the tank should be drained regularly.
10. When the humidity sensor is in a high-humidity state for a long time, the condensation will form, and the humidity display value will remain high. If an accurate humidity display value is required, the incubator door should be opened and the humidity sensor at room temperature. After drying naturally, you can continue to use it.
11. In order to maintain the beauty of the equipment, it is not allowed to wipe the surface with acid or alkali and other corrosive materials. The box can be dried regularly with a dry cloth.
12. If the humidity is not used for a long time, please drain the water inside the box.
13. When the instrument is stopped, unplug the power cord.